Via de acesso volar minimamente invasiva para fraturas da extremidade distal do rádio

Authors

  • Cláudio Roberto Martins Xavier Hospital do Servidor Estadual de São Paulo
  • Roberto Della Torre dos Santos Hospital do Servidor Estadual de São Paulo
  • Júlio Cezar Ferreira Neto Hospital do Servidor Estadual de São Paulo
  • Fernando Luis de Oliveira Aurich Hospital do Servidor Estadual de São Paulo
  • Lucas Gasparetto Bittar Hospital do Servidor Estadual de São Paulo

Keywords:

radius fractures/surgery, minimally invasive surgical procedures, fracture fixation/methods, treatment outcome

Abstract

Open reduction and internal fixation using a blocked volar plate has been an increasingly used technique for distal radius fractures. Both conventional and minimally invasive techniques are used to treat this group of fractures. Despite theoretical differences, more scientific evidence is still being sought to prove which method is superior comparing to clinical and functional results in the postoperative period. The authors describe a case with minimally invasive volar access for fractures of the distal radius and compare it with the conventional technique.

Downloads

Download data is not yet available.

Author Biographies

Cláudio Roberto Martins Xavier, Hospital do Servidor Estadual de São Paulo

Chefe do Grupo de Mão do Serviço de Ortopedia e Traumatologia do HSPE, São Paulo, SP, Brasil

Roberto Della Torre dos Santos, Hospital do Servidor Estadual de São Paulo

Médico Assistente do Grupo de Mão do Serviço de Ortopedia e Traumatologia do HSPE, São Paulo, SP, Brasil

References

Bentohami A, Bosma J, Akkersdijk GJ, van Dijkman B, Goslings JC, Schep NW. Incidence and characteristics of distal radial fractures in an urban population in The Netherlands. Eur J Trauma Emerg Surg. 2014;40(3):357-61.

Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M. A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am. 2011;93(23):2146-53.

Fu YC, Chien SH, Huang PJ, et al. Use of an external fixation combined with the buttress-maintain pinning method in treating comminuted distal radius fractures in osteoporotic patients. J Trauma. 2006;60(2):330-3.

Herrera M, Chapman CB, Roh M, Strauch RJ, Rosenwasser MP. Treatment of unstable distal radius fractures with cancellous allograft and external fixation. J Hand Surg Am. 1999;24(6):

-78.

Rizzolo SJ, Schneider LH, Stewart WG Jr. Fractures of the shaft of the radius after treatment of Colles fractures with pins and plaster or external fixation. J Orthop Trauma. 1993;7(1):78-83.

Strohm PC, Muller CA, Boll T, Pfister U. Two procedures for Kirschner wire osteosynthesis of distal radial fractures: a randomized trial. J Bone Joint Surg Am. 2004;86(12):2621-8.

Chung KC, Squitieri L, Kim HM. Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years. J Hand

Surg Am. 2008;33(6):809-19.

Chung KC, Shauver MJ, Birkmeyer JD. Trends in the United States in the treatment of distal radial fractures in the elderly. J Bone Joint Surg Am. 2009;91(8):1868-73.

Fanuele J, Koval KJ, Lurie J, Zhou W, Tosteson A, Ring D. Distal radial fracture treatment: what you get may depend on your age and address. J Bone Joint Surg Am. 2009;91(6):1313-9.

Mattila VM, Huttunen TT, Sillanpaa P, Niemi S, Pihlajamaki H, Kannus P. Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in

Finland. J Trauma. 2011;71(4):939-42.

Ring D, Jupiter JB, Brennwald J, Bu¨ chler U, Hastings H. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am 1997;22:777-84.

Jupiter JB, Fernandez DL, Toh CL, Fellmann T, Ring D. The operative management of volar articular fractures of the distal end of the radius. J Bone Joint Surg Am 1996;78:1817-27.

Matullo KS, Dennison DG. Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement. Hand (N Y). 2015;10(2):292-6.

Zenke Y1, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T, Nakamura T. Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate

osteosynthesis. J Orthop Trauma. 2011;25(7):425-31.

Armangil M, Bezirgan U, Basarir K, Bilen G, Demirtas M, Bilgin SS. The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eur J Orthop Surg

Traumatol. 2014;24(3):335-9.

Perren SM. Evolution of the internal fixation of long boné fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone

Joint Surg Br. 2002;84(8):1093-110. 17. Abe Y, Yoshida K, Tominaga Y. Less invasive surgery with wrist arthroscopy for distal radius fracture. J Orthop Sci 2013;18(03): 398-404.

Yoshikawa Y, SaitoT, Matsui H. A new cosmetic approach for volar fixed-angle plate fixation to treat distal radius fractures. J Jpn Soc Surg Hand. 2008;24:889-93.

Orbay JL, Touhami A, Orbay C. Fixed angle fixation of distal radius fractures through a minimally invasive approach. Tech Hand Up Extrem Surg 2005;9(03):142-8.

Lee DY, Park YJ, Park JS. A meta-analysis of studies of volar locking plate fixation of distal radius fractures: conventional versus minimally invasive plate osteosynthesis. Clin Orthop Surg.

;11(2):208-19.

Published

2019-08-09

How to Cite

1.
Xavier CRM, Santos RDT dos, Ferreira Neto JC, Aurich FL de O, Bittar LG. Via de acesso volar minimamente invasiva para fraturas da extremidade distal do rádio. RTO [Internet]. 2019 Aug. 9 [cited 2024 Nov. 9];19(3):8-13. Available from: https://rto.emnuvens.com.br/revista/article/view/172

Issue

Section

Artigos